Use of Nuclear Magnetic Resonance Imaging Angiography to Follow-Up Arterial Remodeling in an Animal Model Medizin - Open Access LMU - Teil 11/22

    • Educación

Appropriately sized arteries in small animals may be possible models for studying the remodeling process as occurs after arterial balloon injury in humans. Magnetic resonance imaging (MRI) is able to noninvasively image tissue in vivo. To date, small animal angiog raphy models have mostly used research-dedicated instruments and resolution, which are not universally available.Experiments were carried out on a rat aorta model of remodeling in vivo (n=40). Arteries were injured by oversized balloon dilation; control arteries were uninjured. Angiography imaging was performed immediately before sacrifice with an unmodified clinical MRI unit, a 1.5 Tesla MR tomograph with a 20-cm-diameter coil. Longitudinal MRI pictures of the aorta and morphometry of tissue sections to measure luminal and arterial wall areas were analyzed with use of computer-assisted techniques.Comparison of dimensions demonstrated correlation between MRI and histology measurements of the lumen. MRI and morphometry showed a gradual increase in mean luminal area over 6 weeks following injury. The lumen increase correlated with total arterial area and thickness.In this rat aorta model, remodeling documented at histology was followed-up in vivo. The use of such clinical MRI scanners has potential to reduce animal numbers needed to follow-up the remodeling process after therapeutic intervention.

Appropriately sized arteries in small animals may be possible models for studying the remodeling process as occurs after arterial balloon injury in humans. Magnetic resonance imaging (MRI) is able to noninvasively image tissue in vivo. To date, small animal angiog raphy models have mostly used research-dedicated instruments and resolution, which are not universally available.Experiments were carried out on a rat aorta model of remodeling in vivo (n=40). Arteries were injured by oversized balloon dilation; control arteries were uninjured. Angiography imaging was performed immediately before sacrifice with an unmodified clinical MRI unit, a 1.5 Tesla MR tomograph with a 20-cm-diameter coil. Longitudinal MRI pictures of the aorta and morphometry of tissue sections to measure luminal and arterial wall areas were analyzed with use of computer-assisted techniques.Comparison of dimensions demonstrated correlation between MRI and histology measurements of the lumen. MRI and morphometry showed a gradual increase in mean luminal area over 6 weeks following injury. The lumen increase correlated with total arterial area and thickness.In this rat aorta model, remodeling documented at histology was followed-up in vivo. The use of such clinical MRI scanners has potential to reduce animal numbers needed to follow-up the remodeling process after therapeutic intervention.

Top podcasts en Educación

Inglés desde cero
Daniel
Tu Desarrollo Personal
Mente_Presocratica
LA MAGIA DEL CAOS con Aislinn Derbez
Aislinn Derbez
De Shunsho a Crack - con Nico Muñoz
Nicolas Muñoz
BBVA Aprendemos juntos 2030
BBVA Podcast
Yo Pude, ¡Tú Puedes!
Margarita Pasos y Sofi Pasos

Más de Ludwig-Maximilians-Universität München

GK Strafrecht II (A-K) SoSe 2020 Satzger
Helmut Satzger
NANO-BIO-PHYSICS SYMPOSIUM 07.09.2019 Day 2
Ludwig-Maximilians-Universität München
NANO-BIO-PHYSICS SYMPOSIUM 06.09.2019 Day 1
Ludwig-Maximilians-Universität München
Center for Advanced Studies (CAS) Research Focus Global Health
Center for Advanced Studies
The Wicked Mu
Stephan Kulla und Nils Hansen
Podcast Jüdische Geschichte
Abteilung für Jüdische Geschichte und Kultur, LMU München