HVAC School - For Techs, By Techs

Bryan Orr
HVAC School - For Techs, By Techs

Real training for HVAC ( Heating, Ventilation, Air Conditioning and Refrigeration) Technicians. Including recorded tech training, interviews, diagnostics and general conversations about the trade.

  1. How to Predict Air Flow Issues in the Sales Process

    1小时前

    How to Predict Air Flow Issues in the Sales Process

    Chris Hughes and Steve Rogers from The Energy Conservatory discuss TEC's TrueFlow technology and its crucial role in predicting airflow issues in the sales process, particularly for heat pump retrofits. They explain how the TrueFlow app helps contractors accurately measure both static pressure and airflow in existing systems, enabling them to predict whether proposed equipment changes will work effectively. This is especially vital when considering the growing trend of replacing gas furnaces with heat pumps, as the airflow requirements can differ significantly. The conversation delves into a detailed example of replacing an 80% efficient 48,000 BTU furnace with a heat pump. They demonstrate how the airflow requirement would nearly double from 652 CFM to 1,200 CFM, potentially causing the static pressure to quadruple due to Fan Law 2 principles. This dramatic increase could lead to significant performance issues if not properly addressed during the system design phase. The experts emphasize that using TrueFlow during the sales process allows contractors to identify potential problems and necessary modifications before installation rather than discovering issues during callbacks. The discussion also covers the ideal workflow for system assessment and sales, starting with customer comfort evaluation and proper load calculations. It's important to reduce loads through envelope improvements when possible, particularly in cold climates where heat pump retrofits are becoming more common. Proper system sizing often means going smaller rather than larger, contrary to common industry practices, and the worst HVAC systems are often found in expensive custom homes rather than tract housing. Key Topics Covered: &]:mt-2 list-disc space-y-2 pl-8"> TrueFlow technology and its role in system forecasting Fan Law 2 and its impact on static pressure when changing airflow Heat pump retrofit challenges and considerations The importance of accurate load calculations Dual fuel systems as a solution for cold climates The relationship between airflow and static pressure Sales process integration of technical measurements Common issues with oversized equipment The importance of envelope assessment Methods for reducing system loads Proper duct sizing and modification strategies The role of proper filter sizing and selection The benefits of flat-rate pricing for duct modifications Training resources and support available for TrueFlow users   Check out TEC's YouTube channel at https://www.youtube.com/@energyconservatory, and you can visit TEC's website at https://energyconservatory.com/.   Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool.  Purchase your tickets or learn more about the 6th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android.   Subscribe to our YouTube channel.  Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    47 分钟
  2. MCA is 27 and the Breaker is a 50A - Short #219

    2天前

    MCA is 27 and the Breaker is a 50A - Short #219

    In this short podcast episode, Bryan and Mike from DITEK talk about what to do in tricky electrical scenarios, such as when the MCA is 27 and you have a 50A breaker. When you size an HVAC system for compatibility with voltage monitors, like the DITEK Kool Guard, you need to pay attention to the MCA (minimum circuit ampacity), which should not be confused with MOCP (maximum overcurrent protection or breaker size). As long as the MCA is 40 amps or lower, you can attach the HVAC condenser to the Kool Guard. The KG2 also accepts wire sizes up to 6 AWG. The Kool Guard is NOT a source of overcurrent protection; it is a voltage monitor rated for carrying current, which means ratings will be in MCA, not MOCP. MOCP is designed to deal with high starting amps and lets users know the maximum allowable current for a circuit so that it can trip properly when that current is exceeded. According to Section 440 of the National Electrical Code (NEC), motors with internal overload protection allow for a difference between the MCA and MOCP. You may find higher MOCPs on inverter-driven systems.   Learn more about DITEK at https://www.diteksurgeprotection.com/.  Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool.  Purchase your tickets or learn more about the 6th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android.   Subscribe to our YouTube channel.  Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    6 分钟
  3. Deploying Surge Protection & Voltage Monitoring w/ DITEK

    11月14日

    Deploying Surge Protection & Voltage Monitoring w/ DITEK

    Bryan discusses surge protection devices (SPDs) with Mike from DITEK, focusing on practical applications for HVAC contractors and how to provide value to clients. Mike emphasizes that surge protection is essential for modern HVAC systems, particularly given that they are typically the most expensive appliance in a home and increasingly rely on sophisticated electronic components like variable-speed compressors and inverter boards. The conversation delves into installation best practices, with a detailed discussion of proper wiring techniques for SPDs. Mike explains that surge protectors should be installed in parallel with the circuit, typically at the disconnect, and addresses common concerns about double-tapping lugs and ground connections. He emphasizes the importance of keeping wire lengths as short as possible and provides guidance for installations both with dedicated disconnects and panel-direct connections. A significant portion of the episode focuses on DITEK's Kool Guard (KG2) product, which represents an evolution in HVAC protection by combining surge protection with voltage monitoring. Mike explains how modern HVAC equipment, particularly inverter-driven systems, is increasingly sensitive to both over-voltage and under-voltage conditions. The Kool Guard monitors voltage on each phase independently and provides visual indication of fault conditions through LED indicators, making it easier for homeowners to identify potential issues without opening electrical enclosures. Key Topics Covered: ·        Why every modern HVAC system needs surge protection ·        Installation locations and proper wiring techniques for SPDs ·        The difference between line-side and load-side installation ·        Ground connection best practices ·        How to protect both condensers and air handlers ·        The evolution from basic surge protection to voltage monitoring ·        The importance of voltage monitoring for modern inverter-driven equipment ·        How Kool Guard monitors voltage phase-to-ground vs line-to-line ·        Common power quality issues beyond lightning strikes ·        How to discuss surge protection with customers ·        The limitations of utility-provided surge protection ·        The impact of aging power infrastructure on power quality ·        The advantages of USA-made surge protection products ·        How voltage monitoring prevents damage from brownouts and over-voltage conditions ·        The pre-programmed voltage protection ranges in Kool Guard ·        Visual indication features for fault conditions   Learn more about DITEK at https://www.diteksurgeprotection.com/.  Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool.  Purchase your tickets or learn more about the 6th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android.   Subscribe to our YouTube channel.  Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    36 分钟
  4. Pumping vs. Compression - Short #218

    11月12日

    Pumping vs. Compression - Short #218

    In this short episode, Bryan clears up the confusion behind pumping vs. compression. Pumping is usually associated with liquid. Liquid, like vapor, is a fluid, but it's a lot denser and is essentially incompressible because the molecules are close together. Liquid volume varies based on temperature and density, but we can't squish the molecules together. That's why compressors with very little axial and radial compliance fail when flooded; they can't compress the liquid. A circulator pump in a hydronic system is an example of a pump that pushes liquid along, but the pressure difference across the pump is minimal compared to that of a compressor; the same is true of liquid vs. vapor CO2.  However, vapor molecules are far apart and can be squished together to take up a smaller volume. That's why vapor can go through compressors, which take a fluid of one volume and apply pressure to shrink it to a smaller volume, raising the temperature in the process. Pneumatics, as opposed to hydraulics, utilize compression to move vapor around in a circuit. Recovery machines need to be able to compress vapor refrigerant and pump liquid into the recovery tank. Compressors and pumps can either be positive displacement or non-positive displacement systems. A positive displacement system creates a trap and forces a fixed amount of fluid through a system, like a scroll compressor or a circulator pump. Refrigerant volumes may vary because vapor density varies with temperature and pressure (the volume flow is the same, but the mass flow varies). A condensing fan motor, on the other hand, is dynamic and varies the volume of air it moves in response to pressure, as the mechanism relies on velocity and kinetic energy to move air.   Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool.  Purchase your tickets or learn more about the 6th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android.   Subscribe to our YouTube channel.  Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    10 分钟
  5. Building Tech Confidence w/ Refrigeration Mentor

    11月7日

    Building Tech Confidence w/ Refrigeration Mentor

    Trevor Matthews returns to the HVAC School Podcast to discuss building tech confidence and personal growth in the HVAC and refrigeration industry. The conversation explores the transformative power of self-investment, continuous learning, and maintaining a positive mindset. Trevor shares his personal journey from a hesitant technician to a successful business owner, highlighting the importance of pushing beyond comfort zones and embracing continuous improvement. Some fundamental mindset shifts are necessary for professional development. Trevor candidly discusses his early career struggles, including his initial fear of public speaking and technical challenges. He emphasizes that confidence isn't something that happens overnight but is built through consistent effort, studying, and maintaining a willingness to learn. The key to the growth mindset is to focus on personal progress instead of comparing your achievements to those of others, and it's a perspective that can dramatically impact professional and personal growth. Self-investment consists of dedicating time to learning, staying physically and mentally healthy, and maintaining a positive attitude, and it can open up unprecedented opportunities. Many technicians have transformed their careers by adopting a growth mindset, continuously seeking knowledge, and being willing to step outside their comfort zones. Key Topics Covered: Building professional confidence The importance of continuous learning Overcoming fear and self-doubt in technical careers Strategies for personal and professional growth Maintaining a positive mindset Investing in self-improvement Balancing work, health, and personal development The power of small, consistent actions Avoiding comparison with others Techniques for staying motivated Recommended resources for personal development Recommended Resources Mentioned: Book: "Limitless" by Jim Kwik Book: "Good to Great" by Jim Collins Book: "Think and Grow Rich" by Napoleon Hill Book: "Mastery" by Robert Greene Podcast: Hidden Brain Podcast: AC Service Tech   Check out Refrigeration Mentor at https://refrigerationmentor.com/ or email Trevor at trevor@refrigerationmentor.com.  Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool.  Purchase your tickets or learn more about the 6th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android.   Subscribe to our YouTube channel.  Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    47 分钟
  6. Molecular Transformator - Short #217

    11月5日

    Molecular Transformator - Short #217

    In this short podcast episode, Bryan talks about the CPS Molecular Transformator and what it does. The Molecular Transformator is a version of a tube-in-shell heat exchanger, which is a method of exchanging heat from one fluid medium to another fluid medium. Tubes containing a fluid pass through a shell containing water or glycol, and there is a heat exchange between that secondary fluid and the fluid being circulated in the tubes. In a Molecular Transformator, the fluid being circulated is recovered refrigerant, and the secondary fluid is water (in a bucket), which absorbs heat from the refrigerant and cools it down to make sure that the refrigerant enters the recovery tank as a liquid. Refrigerant recovery machines have condensers inside of them, but they are quite small and don't hold a lot of refrigerant by design; many recovery machines use microchannel coils. A lot of the time, the refrigerant leaving a recovery machine is a liquid-vapor mix and too high-temperature; a lot of people run a hose over the tank or put it in a bucket of ice. The "Molecular Transformator" tries to settle the vapor molecules down into a liquid; it transforms the vapor molecules using the same mechanism as a tube-in-shell heat exchanger. The main issue is that there will be leftover refrigerant in the Molecular Transformator after recovery. However, you can mitigate this problem with ball valves and proper purging. Do so responsibly to avoid venting refrigerant.   Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool.  Purchase your tickets or learn more about the 6th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android.   Subscribe to our YouTube channel.  Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    9 分钟
  7. Surge Protection Basics w/ DITEK

    10月31日

    Surge Protection Basics w/ DITEK

    In this enlightening episode, we sit down with Mike, a 20-year veteran from DITEK, a leading American manufacturer of surge protection devices based in Largo, Florida. The conversation begins with a brief discussion about recent hurricane impacts in the Tampa Bay area, where DITEK maintains its 65,000-square-foot manufacturing facility. Mike shares how the company, despite facing challenging weather conditions, continued its operations and maintained its commitment to American manufacturing. The bulk of the discussion centers around surge protection technology and its critical importance in protecting HVAC systems and other electronic equipment. Mike provides an excellent analogy, comparing surge protectors to pressure relief valves for electrical systems. He explains how Metal Oxide Varistors (MOVs) work as semiconductors that create low impedance paths to ground when voltage exceeds certain thresholds. The conversation delves into the evolution of MOV technology, particularly the development of thermally protected MOVs that provide enhanced safety features. The episode also addresses common misconceptions about surge protection, particularly the belief that surge protectors are primarily for lightning protection. Mike explains that while lightning strikes are a concern, especially in areas like Florida, approximately 65% of surges actually originate from within facilities themselves, often from equipment cycling on and off or other power quality issues. He emphasizes the importance of proper installation, particularly regarding ground connections and lead lengths, noting that every six inches of wire length can add about 100 volts to the clamping voltage of the device. Key Topics Covered: DITEK's history and commitment to American manufacturing Basic principles of surge protection and how MOVs work Evolution of MOV technology and thermal protection features Difference between transient voltage and temporary overvoltage (TOV) Importance of proper grounding and lead length in surge protection Cascading surge protection strategy for comprehensive protection UL testing standards and voltage protection ratings (VPR) Common misconceptions about surge protection Impact of aging electrical infrastructure on power quality Importance of customer support and ethical business practices Installation best practices for surge protection devices Relationship between ground resistance and surge protector performance Types of surge protective devices (SPD) and their classifications   Learn more about DITEK at https://www.diteksurgeprotection.com/.  Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool.  Purchase your tickets or learn more about the 6th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android.   Subscribe to our YouTube channel.  Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    39 分钟
  8. Q&A - Am I Toxic For Caring? - Short #216

    10月29日

    Q&A - Am I Toxic For Caring? - Short #216

    Bryan answers a listener-submitted question: "Am I toxic for caring?" He gives advice on how to maintain professional relationships while still maintaining very high standards of quality for your own work. Having high standards is great, but it can be frustrating when you perceive coworkers as having lower standards than you. A poor-quality end product is fairly objective, but other ways of judging coworkers' standards are a lot more subjective and may vary by culture, and we end up judging the person rather than the work. While we should care about the objective outcomes of a job, we want to challenge ourselves when we start comparing others' work to our own unfavorably. Judging others' work isn't inherently bad or "toxic," but it has to be controlled and done in service of something greater. When we confront others or judge their work, we need to make sure it comes from a place of professional pride (rather than personal pride) and personal humility. As tradespeople, we don't always do the best work, either. In some mission-critical applications, we need to rely on workarounds to get a quick outcome. In those situations, it's a lot more important to be honest about what we're doing and the value we promise. When we find opportunities for our colleagues to do things better, we can offer advice in service of the job and allow the other person to take it or leave it; we don't get to decide that for others. We also have to acknowledge that people have different natural inclinations, and we'd be wise to respect those differences.   Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool.  Purchase your tickets or learn more about the 6th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android.   Subscribe to our YouTube channel.  Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    17 分钟

主持人与嘉宾

4.9
共 5 分
955 个评分

关于

Real training for HVAC ( Heating, Ventilation, Air Conditioning and Refrigeration) Technicians. Including recorded tech training, interviews, diagnostics and general conversations about the trade.

你可能还喜欢

若要收听包含儿童不宜内容的单集,请登录。

关注此节目的最新内容

登录或注册,以关注节目、存储单集,并获取最新更新。

选择国家或地区

非洲、中东和印度

亚太地区

欧洲

拉丁美洲和加勒比海地区

美国和加拿大