HVAC School - For Techs, By Techs

Bryan Orr

Real training for HVAC ( Heating, Ventilation, Air Conditioning and Refrigeration) Technicians. Including recorded tech training, interviews, diagnostics and general conversations about the trade.

  1. 14 HR AGO

    Dehum Innovations and Essentials w/ Nikki K.

    In this live episode recorded at the AHR Expo 2026 Podcast Pavilion in Las Vegas, host Bryan sits down with longtime friend and industry expert Nikki Krueger of Santa Fe and AprilAire. Nikki brings over 15 years of experience in indoor air quality and whole-home dehumidification to the conversation, having started her career with AprilAire before moving to Santa Fe (formerly Ultra Aire) — and now coming full circle as the two brands have integrated under the AprilAire umbrella as of January 1st of this year. The episode dives deep into a topic close to both hosts' hearts: how to properly manage indoor humidity, and what role a whole-home ventilating dehumidifier plays in a comprehensive HVAC system strategy. Bryan and Nikki lay out a holistic framework for tackling moisture problems, emphasizing that a dehumidifier should be the last tool added — not the first. Before reaching for dedicated dehumidification equipment, contractors need to assess the building envelope for air leaks, evaluate whether the air conditioning system is properly sized (oversizing is a major contributor to poor latent removal), confirm that the AC is set up with the right airflow and sensible heat ratio, and take into account the ventilation strategy and occupant behavior. The pair discuss real-world scenarios ranging from elderly residents in Florida who keep their thermostats at 80°F, to a project in Barbados where overcooling caused interstitial condensation in walls and ceilings. The message is clear: humidity control is a systems problem, not a single-product fix. A significant portion of the episode is dedicated to proper installation practices for whole-home dehumidifiers. Nikki explains why Santa Fe recommends pulling from a dedicated return and discharging into the supply side of the AC duct — rather than tying into the return side — because the heat generated by dehumidification (roughly 1,054 BTUs per pint of water removed) can warm the AC evaporator coil and reduce its latent removal capacity. Bryan adds nuance around dew point management when routing outdoor air ducts, and both hosts agree that fan operation strategy (continuous low-speed vs. intermittent) matters more in tight, low-load homes where mixing is harder to achieve naturally. They also clarify a common misconception: a ventilating dehumidifier is not a dedicated outdoor air system (DOAS) and does not automatically condition incoming ventilation air before it enters the home. The conversation wraps up with an exciting look at Santa Fe's newly launched Ultra V Series, which features an upgraded 8-inch ventilation duct (up from 6 inches), a more powerful fan for handling higher static pressure in retrofit applications, a new digital control panel, and a wired remote humidity sensor that can be placed in the living space for more accurate readings. Nikki and Bryan also field audience questions on topics like short-cycling risks from oversized dehumidifiers and why Santa Fe chose a wired sensor over wireless (accuracy, reliability, and fewer callback headaches). Bryan closes by noting that rising dew points across most U.S. markets over the last 20 years make whole-home dehumidification more relevant than ever — and that any region where you can see green grass outside is a candidate for a more advanced moisture control strategy. Topics Covered Introduction to Nikki Krueger and the merger of Santa Fe and AprilAire under one brand The purpose of whole-home ventilating dehumidifiers and how they fit into an overall HVAC system strategy Latent vs. sensible heat loads explained — and why both matter for comfort and moisture control Geographic reach of humidity problems — why dehumidification isn't just a Florida or Gulf Coast issue Ken Gehring ("Teddy Bear"), inventor of the whole-house ventilating dehumidifier, and his framework for diagnosing moisture problems The four-factor checklist before deploying a dehumidifier: building envelope, AC sizing, AC setup/airflow, and ventilation strategy How occupant behavior (thermostat preferences, activity levels, large households) creates latent load variability The dangers of overcooling — how setting thermostat too low can cause interstitial condensation in walls, ceilings, and attics Sensible heat ratio (SHR) and its role in a system's ability to remove moisture — targeting ~350 CFM per ton in humid climates Why dehumidifiers should connect to a dedicated return and discharge into the supply — not tie into the AC return side How dehumidifier heat output (~1,054 BTUs per pint) can reduce AC coil efficiency when ducted incorrectly Fan-on strategy debate: when running continuous low-speed circulation helps vs. hurts humidity control Tighter homes, smaller systems, and the importance of air mixing strategies (including ceiling fans)  Ventilating dehumidifiers vs. dedicated outdoor air systems (DOAS) — clearing up a common misconception about how ventilation air is conditioned Dew point management for outdoor air ducts — preventing condensation inside duct runs Using dehumidifiers to address sweating ductwork in multi-story homes Rising dew points over the past 20 years and what "green grass climates" means for dehumidification demand Heat pump oversizing challenges in colder climates and the downstream impact on AC latent removal Santa Fe's new Ultra V Series: 8-inch ventilation duct, stronger fan, digital controls, and wired remote humidity sensor Why proper dehumidifier sizing matters: short-cycling risks, moisture reservoir release, and uneven RH throughout the home Why Santa Fe chose a wired humidity sensor — accuracy, reliability, and reducing contractor callbacks Audience Q&A: oversizing consequences, short-cycling mechanics, and sensor placement best practices   Learn more about Santa Fe Dehumidifiers at santafeproducts.com.  Connect with Nikki Krueger on LinkedIn or Instagram @nikkikruegerIAQ. Check out the work of Ken Gehring ("Teddy Bear") or ask him a question on the HVAC Talk Forum: hvac-talk.com. Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool. Purchase your tickets or learn more about the 7th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android. Subscribe to our YouTube channel. Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    51 min
  2. 2 DAYS AGO

    Lifetime of HVAC/R w/ John Pastorello - Short #279

    In this short podcast episode from AHR Expo 2026, Bryan sits down with John Pastorello for a discussion about the latter's lifetime of HVAC/R. John was a chemist and an HVAC technician before founding Refrigeration Technologies in 1987, and he received the HVAC Tactical Lifetime Achievement Award in 2026. Prior to entering the trade, John was a chemist in a lab. He applied for and was hired by an HVAC company when he realized the financial opportunity in the trade. He eventually owned a contracting business, but he didn't truly make his HVAC/R chemistry debut until 1987 with Big Blu. When he noticed problems with existing liquid leak reactants and inaccurate electronic leak detectors, John developed Big Blu in his kitchen (with the help of his local library and patent office for research) and tested it in the field.  Big Blu was the first Refrigeration Technologies product, and it was the only one for a while. He then developed Nylog in the early 1990s while developing a different product. After falling down research rabbit holes and doing lots of trial and error, he eventually realized the product's potential as an assembly lubricant, and Nylog became an official Refrigeration Technologies product. Even as Refrigeration Technologies continues to grow and has received several purchase offers, it remains a family business. John's son, Mike, became a mechanic but eventually decided to return to the business, and he runs it to this day. John's career culminated with the HVAC Tactical Lifetime Achievement Award, which is a testament to the service, education, and mentorship he has shared with the HVAC/R industry.   Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool. Purchase your tickets or learn more about the 7th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android. Subscribe to our YouTube channel. Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    20 min
  3. 12 FEB

    Vapor Injection + Modulation Innovation w/ Copeland

    In this live episode from the AHR 2026 Podcast Pavilion, Bryan sits down with Copeland's Josh Souders (Manager of Commercial Unitary Product Management) and Jeff Kukert (Compression Senior Technical Trainer) to dive deep into Enhanced Vapor Injection (EVI) technology and its transformative impact on HVAC systems. This conversation offers both technical professionals and industry newcomers a comprehensive look at how vapor injection is revolutionizing heat pump performance, particularly in challenging climate conditions. The discussion centers on how EVI technology addresses one of the industry's most persistent challenges: maintaining high heat pump capacity in extremely low-temperature conditions. Josh and Jeff explain that vapor injection can deliver up to 20% added capacity and 10% improved efficiency while simultaneously enhancing compressor reliability. This technology, which has been a staple in refrigeration applications for years, is now becoming increasingly prevalent in commercial and residential HVAC systems, especially as cold climate heat pumps gain traction across North America. The guests make the complex topic accessible by breaking down how the system works—taking liquid refrigerant from the condensing line, running it through an expansion device and brazed plate heat exchanger (economizer), and injecting the cooled vapor directly back into the compressor scroll at a specific intermediate point. What makes this episode particularly valuable is the practical guidance offered for field technicians. The conversation moves beyond theoretical explanations to address real-world implementation challenges and troubleshooting strategies. Josh and Jeff emphasize the importance of understanding operating envelopes, pulse-width modulated (PWM) valves, pressure transducers, and modern control systems. They introduce Copeland's latest product developments, including the YAW variable speed vapor injection platform (1.5 to 25 tons) and the upcoming YAB two-stage vapor injection system launching later in 2026. The discussion also touches on applications beyond traditional HVAC, including commercial water heating and boiler replacement systems where high discharge temperatures are crucial. Throughout the episode, the guests maintain an encouraging tone toward technicians who may feel intimidated by these advancing technologies. They stress that while EVI systems may appear complex with additional tubing, heat exchangers, valves, and sensors, the underlying thermodynamic principles remain the same. The key is familiarizing oneself with new components like PWM valves and modern controllers, and leveraging tools like Copeland Mobile to verify system performance against operating envelopes. This episode serves as both an educational resource and a call to action for HVAC professionals to embrace these emerging technologies that are rapidly becoming industry standard. Topics Covered Enhanced Vapor Injection (EVI) fundamentals – How EVI works, its history in refrigeration, and why it's now critical for commercial and residential HVAC applications Capacity and efficiency benefits – Achieving up to 20% capacity boost and 10% efficiency improvement, particularly in low-ambient heating conditions Compressor reliability improvements – How injecting cooled vapor into the scroll set manages discharge temperatures and extends compressor life under high compression ratios Operating envelope management – Understanding compressor operational limits and using tools like Copeland Mobile to verify field conditions stay within safe parameters Cold climate heat pump technology – Meeting DOE's Cold Climate Heat Pump Challenge requirements for 100% capacity at 5°F ambient conditions System architecture and components – Detailed explanation of economizers (brazed plate heat exchangers), pulse-width modulated (PWM) valves, pressure transducers, and advanced controllers Compression ratio challenges – Managing the increased work required when outdoor temperatures drop while indoor condensing temperatures remain constant New Copeland product platforms – Introduction to YAW variable speed vapor injection (1.5-25 tons), YAB two-stage vapor injection (launching 2026), and tandem variable speed configurations Applications beyond traditional HVAC – Water heating systems, commercial boiler replacement, and managing high discharge temperatures for Legionella protection Technician training and tools – Practical advice on learning PWM valves, thermistors, transducers, and system controllers; emphasis on using Copeland Mobile for dynamic performance analysis Market trends and adoption – How vapor injection is becoming standard in premium residential systems and increasingly common across commercial rooftop units and dedicated outdoor air systems Installation and service considerations – Proper system design to avoid oversizing, humidity control in hot-humid climates, and troubleshooting techniques for complex control systems   Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool. Purchase your tickets or learn more about the 7th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android. Subscribe to our YouTube channel. Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    51 min
  4. 10 FEB

    TXV vs. EEV - Short #278

    In this short podcast episode, Bryan breaks down the differences between a thermostatic expansion valve (TXV) and an electronic expansion valve (EEV). He highlights their strengths and weaknesses. In the basic refrigerant circuit, the metering device drops the pressure. TXVs and EEVs are both metering devices that cause the liquid refrigerant to drop in pressure and become a liquid-vapor mixture; they control evaporator feeding and maintain a constant superheat. TXVs achieve this by mechanical means; the bulb responds to suction line temperature and evaporator pressure at the valve. They are self-contained and easy to diagnose with basic refrigeration measurements. However, they are prone to mechanical failures, including clogged orifices and screens, cracked capillary tubes, and powerhead leaks. Installation errors are also easy to make, and TXVs can hunt in low-load conditions. Overall, failures are often mechanical and refrigerant-related. They win in the simplicity department. EEVs receive inputs from sensors and modulate in response to those digital signals. They have a wider modulation range and maintain stable control in low-superheat applications, and they do well in conditions with highly variable loads or where coordination across multiple coils is required. EEVs come in two types: stepper motor (small, discrete steps) and PWM (controlled solenoid valves). Stepper-style EEVs excel at fine positioning, and PWM-style EEVs are in applications that require a more robust valve (like CO2 refrigeration). EEV failures are often electromechanical or related to sensor control. They win in the controllability department. There is no "best" metering device; they merely have different strengths that make them better suited to different applications. However, EEVs are the future due to the greater degree of controllability we will need in newer equipment. Commissioning and airflow are also crucial for getting the most out of both metering device types in terms of longevity and reliability.   Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool. Purchase your tickets or learn more about the 7th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android. Subscribe to our YouTube channel. Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    12 min
  5. 5 FEB

    Electric Heat Talk w/ Bert

    In this informative episode, host Bryan welcomes guest Bert for an in-depth discussion on the often-overlooked but critically important topic of electric heat in HVAC systems. The conversation takes listeners through both the common and uncommon issues that arise with electric heat installations, offering practical insights drawn from years of field experience. Bryan and Bert balance technical expertise with relatable storytelling, making complex electrical concepts accessible to both HVAC professionals and homeowners interested in understanding their heating systems. The discussion begins with some of the more dramatic (and rare) scenarios, including tales of objects left on heat strips during installation—from instruction manuals to spray glue cans—that have led to fires and property damage. These cautionary tales serve as memorable reminders of the importance of proper installation practices. The conversation then shifts to the far more common issues technicians encounter regularly, particularly loose electrical connections. With electric heat strips drawing substantial continuous amperage—often 20 amps per 5kW or more—poor connections can quickly lead to melted wire nuts, damaged terminal blocks, and potentially dangerous situations. Bryan and Bert emphasize that these connection problems often don't manifest until the heating season begins, making proper installation and inspection critical. Bryan and Bert also address widespread confusion around emergency heat versus auxiliary heat, explaining why emergency heat settings are largely obsolete in most modern heat pump applications. They clarify that in typical residential installations with 5-10kW heat strips, the electric backup cannot efficiently heat an entire home on its own, making the emergency heat function impractical. Instead, auxiliary heat should work in tandem with the heat pump to supplement heating during extremely cold conditions or defrost cycles. The hosts advocate for implementing lockout controls that prevent auxiliary heat from activating unless outdoor temperatures drop below 40 degrees, helping homeowners avoid unnecessarily high electricity bills while still maintaining comfort. The technical discussion extends to critical safety mechanisms, including interlocks, thermal overloads, and fusible links that prevent catastrophic failures. Bryan provides historical context on how interlock systems have evolved from high-voltage relay-based designs to modern control board logic, while warning against improper retrofitting that can create new hazards. The episode concludes with practical guidance on proper sizing, voltage considerations, airflow requirements, and the economics of electric heat versus other fuel sources. Throughout the conversation, Bryan and his guest stress that while electric heat is simple and reliable, it demands respect for proper electrical practices and thoughtful system design to ensure both safety and cost-effectiveness. Topics Covered Installation Horror Stories and Safety Hazards: Objects left on heat strips causing fires, including the infamous spray glue can incident Loose Electrical Connections: The #1 issue with electric heat systems and why continuous high amperage makes proper connections critical Wire Sizing and Breaker Matching: Common mistakes when replacing furnaces with heat pumps and the dangers of undersized wiring Emergency Heat vs. Auxiliary Heat: Why emergency heat is largely obsolete in modern residential applications and when auxiliary heat should actually engage Heat Output Calculations: Understanding BTU production per kilowatt (3.41 BTUs per watt) and why 5-10kW strips can't heat most homes alone Lockout Controls and Outdoor Thermostats: Implementing temperature-based restrictions to prevent unnecessary auxiliary heat operation above 40°F Interlock Systems Evolution: How blower/heat strip safety interlocks have changed from relay-based to control board logic Thermal Overloads and Fusible Links: The two types of safety devices that prevent overheating and fire hazards Defrost Cycle Operation: How auxiliary heat integrates with heat pump defrost sequences Balance Point and Dual Fuel Considerations: Economic and operational factors in choosing between electric and gas backup heat Voltage Variations and Sizing: Working with different voltage ratings (208V vs. 240V) and how they affect heat output Diagnostic Techniques: Using Ohm's law and resistance measurements to verify heat strip operation and specifications Airflow Requirements: Why proper air movement is critical for preventing overload trips and premature failures Electrical Safety Practices: Avoiding dangerous shortcuts like bypassing thermal limits or using undersized relays Energy Efficiency and Economics: Comparing the true cost-effectiveness of electric heat versus gas and heat pump operation   Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool. Purchase your tickets or learn more about the 7th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android. Subscribe to our YouTube channel. Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    31 min
  6. 3 FEB

    Vapor Diffusion Ports, Hygric Buoyancy, and Fruit - Short #277

    In this short podcast episode, Bryan talks about some building science concepts, including vapor diffusion ports, hygric buoyancy, and... fruit packaging? Much of building science wisdom over the past couple of decades has dealt with air sealing (just seal it tighter!). However, building tightness has a darker side: more difficulty drying. When buildings can't dry, moisture accumulates and leads to rot. Air leaks and vapor diffusion are NOT the same thing. Vapor diffusion refers to water vapor diffusing through surfaces into the home (through the materials of walls, floors, etc.). Air moves much more water than vapor diffusion, so air leaks are a bigger problem in terms of moisture. Therefore, air barriers matter more than vapor barriers... until the air barrier battle has been won. Hygric buoyancy refers to moist air's lower density than dry air, so wet air rises toward the attic (and then the attic peaks). While sealed attics are excellent, moisture can accumulate at the roof deck, especially when the roofing cools at night. The condensation is worsened by using open-cell foam, as open-cell foam is air-closed but vapor-open (whereas closed-cell foam is air-closed AND vapor-closed). Drying isn't needed if you can KEEP the moisture out of closed-cell foam. Open-cell foam requires a place for vapor to go. Vapor diffusion ports are airtight, controlled vapor-open outlets at the highest points of sealed attics. A cap protects them from bulk water, and they consist of a membrane that blocks air but allows vapor to exit. Unlike a ridge vent, ventilation is not the goal of a vapor diffusion port; it is drying by diffusion rather than airflow and acts as a controlled pressure-relief valve for moisture. Vapor diffusion ports have been proven to be effective at drying and preventing roof rot in humid climates (but NOT ALL climates). They do not work against bulk water intrusion, in cold climates, or when used as vents. Vapor diffusion ports work like fruit packaging, which is designed to let oxygen in and CO2 out, while controlling moisture and slowing decay.   Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool. Purchase your tickets or learn more about the 7th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android. Subscribe to our YouTube channel. Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    14 min
  7. 29 JAN

    Gas & Combustion Safety w/ Bert

    In this informative episode, Bryan and Bert dive deep into gas appliance safety and combustion analysis from the unique perspective of Florida HVAC technicians. While they humorously acknowledge that Florida's mild winters mean they don't work on gas furnaces daily, they make a compelling case that this actually makes their training even more critical. When technicians only encounter gas appliances occasionally, the stakes are higher—which is why they've developed rigorous protocols to ensure safety every single time. The conversation covers everything from the basics of gas leak detection to the nuances of carbon monoxide monitoring, combustion air zones, and proper venting. Bryan and Bert share real-world stories of dangerous situations they've encountered, from exploding pool heaters to improperly capped gas lines at vacation rentals. Their approach emphasizes that every gas leak is your problem when you're on site, regardless of why you were originally called out. This episode is packed with practical wisdom for both seasoned professionals working in gas-heavy markets and those who encounter these systems less frequently. Throughout the discussion, the hosts stress fundamental safety principles that apply across all markets: using your nose to detect leaks, understanding the difference between unspent gas and carbon monoxide, ensuring proper combustion air zones, and never ignoring warning signs like delayed ignition or flame rollout. They also tackle common misconceptions about equipment like flexible gas connectors, orphaned water heaters, and the real risks of cracked heat exchangers.  The conversation wraps up with important reminders about company lockout/tagout procedures, the critical importance of low-level carbon monoxide detectors, and the tools every technician should carry. Bryan and Bert's candid, no-nonsense approach makes complex safety topics accessible while never losing sight of how serious the consequences can be when gas work goes wrong. Topics Covered Gas leak detection and response protocols - Why every gas leak on site becomes your responsibility, using your nose as the first line of defense, and never leaving a leak for someone else to fix Carbon monoxide safety and monitoring - Understanding CO as a combustion byproduct, the limitations of standard UL-rated detectors, and the critical importance of low-level CO monitors Combustion air zones and depressurization - Identifying risks from sealed spaces, return air leaks, exhaust fans, and other equipment that can create dangerous negative pressure Delayed ignition and flame rollout - Recognizing warning signs, understanding causes, and why you should never ignore scorched wires or tripped rollout switches Proper gas line assembly and materials - Selecting appropriate materials for different environments, avoiding flexible connector failures, and ensuring proper sizing Combustion analysis fundamentals - Measuring CO levels in the flue, targeting air-free CO under 100 ppm, and understanding when adjustments are needed Natural draft vs. induced draft systems - Differences in safety considerations, orphaned water heaters, and the myth of oversized flue pipes Venting requirements and back drafting - Identifying improper venting, looking for evidence of back draft on water heaters, and ensuring proper flue design Gas pressure testing and adjustment - When to adjust and when not to, reading data tags, and understanding that most flame problems are air-related, not gas pressure Cracked heat exchangers in context - Why they're less common in warm climates, the role of proper airflow, and focusing on actual safety risks vs. edge cases Tools and equipment recommendations - Combustion analyzers, personal protective CO detectors, combustible gas detectors, precision manometers, and low-level CO alarms Lockout/tagout procedures - Following company protocols, communicating clearly with customers, and balancing safety requirements with homeowner autonomy   Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool. Purchase your tickets or learn more about the 7th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android. Subscribe to our YouTube channel. Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    45 min
  8. 27 JAN

    WHY SQUARE FOOTAGE ≠ TONNAGE - Short #276

    In this short podcast episode, Bryan dives a bit into equipment sizing rules of thumb and why square footage does NOT equal tonnage in today's world. Many rules of thumb exist in the industry, and one is a load calculation rule stating that you can size the HVAC for a house at 500 square feet per ton.  Old houses are leaky and poorly insulated compared to new homes, which results in large energy loads but allows the homes to dry themselves out, as moisture could leak out before it could cause trouble indoors. Large loads and leaky envelopes made 500-600 square feet per ton a sensible rule.  Homes built within the last few decades have a lot more insulation and are tighter, and they have smaller sensible heat loads. However, they're a lot more moisture-prone, especially when moisture can't escape via proper ventilation paths. The 500 square-foot rule of thumb overshoots the latent capacity and leads to short cycling due to oversized equipment. Enter ACCA Manual J, which presents a load calculation method that is very good, but it has barriers to entry; it is very rigorous, has a learning curve, and can be a hassle. One thing is clear, though: load management is key, especially latent load management. At this time, we measure energy efficiency in terms of metrics like SEER, but the future is pointing to peak load management as the answer: getting the right power draw at the right moments instead of high general efficiency. Modernizing hot deck-cold deck systems with steady-state, constantly running systems might be the way to go, especially if we utilize energy storage and modern variable-speed technologies. The new rule of thumb is to think like a building scientist and apply new tools to concepts that have stood the test of time. Low peak loads and steady-state operation are often the way to go with high latent loads in homes built to the most recent building codes and standards.   Have a question that you want us to answer on the podcast? Submit your questions at https://www.speakpipe.com/hvacschool. Purchase your tickets or learn more about the 7th Annual HVACR Training Symposium at https://hvacrschool.com/symposium. Subscribe to our podcast on your iPhone or Android. Subscribe to our YouTube channel. Check out our handy calculators here or on the HVAC School Mobile App for Apple and Android.

    13 min

Hosts & Guests

About

Real training for HVAC ( Heating, Ventilation, Air Conditioning and Refrigeration) Technicians. Including recorded tech training, interviews, diagnostics and general conversations about the trade.

You Might Also Like